Milliohm Meter, Battery Tester, Internal Resistance Measurement, 1.0-1500mΩ, 2.7-16V

Milliohm meter using the AC four-terminal method, ideal for monitoring battery degradation.

Product description

  • Ideal for battery characteristic matching and other applications.
  • In addition to measuring internal resistance, it can also measure very small resistance values of PCB traces and cables.
  • Because it uses an AC application method, it is possible to measure batteries during charging or discharging.
    You can observe the dynamic changes in internal resistance during charge/discharge cycles.
  • We also offer module versions IW7817-IS and IW7817-CS, which allow numerical data to be read out by a microcontroller.

Measurement Example (Video)

This video shows an example of measuring the internal resistance of an aged 6V lead-acid battery using the IW7807.
Since it uses the four-terminal method, four probes are connected.

Although the voltage reading of this lead-acid battery shows 6.14V and appears normal at first glance, a high internal resistance exceeding 130 mΩ is observed.
Normally, this type of battery should exhibit an internal resistance of about 10–20 mΩ, indicating that sulfation due to aging has occurred.
In this way, by measuring internal resistance, hidden degradation that is not visible from voltage readings alone can be directly identified.

Note: In the video, the IW7807 board has been removed from its case for filming purposes.

Specifications

Measurement Item Description
Measurement Method AC current application, four-terminal method (Measurement frequency: 5 kHz, Measurement current: 40 mA, Open circuit voltage: 5 V)
Resistance Measurement Range 1.0–1,500 mΩ
Voltage Measurement Range 2.7 V–16 V
Resistance Resolution 10 μΩ
Voltage Resolution 0.01 V
Power Supply 9 V DC (AC adapter jack: inner diameter 2.1 mm, outer diameter 5.5 mm)
Current Consumption Approximately 60 mA
Display 16x2 LCD display
Board Dimensions W96.0mm × H54.0mm
Terminals Compatible with AWG26–14 (0.12sq–2sq) wires, M2.6 screw terminals

Package Contents

  • IW7807 main unit
  • AC adapter

Precautions

  • Only the internal resistance of DC sources such as batteries or DC power supplies can be measured.
    Do not apply AC sources, as it may cause malfunction or damage.
  • For highly accurate measurements, please use a calibrated measuring instrument.

Related Keywords

Internal resistance, battery internal resistance, battery degradation measurement circuit, inner resistance measurement, milliohm meter, battery tester, lithium-ion battery internal resistance, nickel-metal hydride internal resistance, battery internal resistance, DIY internal resistance meter, internal impedance, battery impedance, battery matching.

Documents and software

Purchase

Out of stock

To request a pre-order, please contact us. Inquiry form

102.07 USD

Volume pricing
QuantityUnit price
1102.07 USD
1091.03 USD

Product information

SKU
352
Manufacturer
Tokyo Devices
Model number
IW7807-KIT
EAN
4560457401349
Released on
Series